1-888-264-5776

Follow Nationwide Coils on LinkedIn Follow Nationwide Coils on Facebook Follow Nationwide Coils on Twitter
Return to Navigation

Category Archives: Coil Facts

Dirty Condenser Coils

Dirty Condenser Coils

The condenser coils of commercial air cooled chillers and package units are one of the most critical and expensive components of the machine. This makes maintenance of the condenser coil a high priority, ensuring proper operation of the entire refrigeration system. When the coils become dirty and corroded there are several negative results that can […]

Read More

1″ Steam Distribution Coils

Steam Coils

Nationwide Coils is excited to announce the addition of 1″ Steam Distribution Coils to our 15 business day standard production. With newly increased capabilities we are now offering a more cost effective higher quality solution for all 1″ steam distribution Coils. The primary purpose for 1″ steam distribution coils as opposed to 5/8″ is increase […]

Read More

Steam Coils

Steam Coils

Steam has been a primary sources of heating for over a 100 years commonly used for heating large commercial buildings and facilities across the country. There are many benefits to steam heating over hot water heating. Steam has a very high temperature as it enters the steam coil for example 5 PSI steam has temperature […]

Read More

AAON DX Evaporator Coil

AAON DX Evaporator Coil

If you are in need a replacement AAON DX evaporator coil Nationwide Coils has the capabilities to manufacture these complex evaporator coils. What makes them unique is there header configuration, the suction lines are at the top of the coil compared to standard configurations of the connections coming from the bottom of the coil. This […]

Read More

Hot Water Coils

Hot Water Coil

Nationwide Coils is a leading manufacturer of hot water coils with design and manufacturing capabilities to supply you with the perfect fit replacement HVAC heating coil. Hot water coils are common products used for heating a variety of buildings and facilities across the united states and are an effective water to air method to heating […]

Read More

Trane SXHFC75 Condenser Coils

SXHFC75

The Trane SXHFC75 Air Cooled Chiller is a common unit that we often have request to manufacture direct replacement coils. This is a large 75 Ton unit with two identical opposite end condenser coils that have a fin height of 60″  X fin length 96″ X 4 rows making them very large coils. The coils […]

Read More

Heating Coils – Polar Vortex 2015

There is no question last winter was cold and this year they are predicting much of the same bitterly cold temperatures that we are familiar with. Are your heating coils broken, leaking or beyond repair? No problem Nationwide coils manufactures direct replacement heating coils for all applications – Steam Coils – Steam Distribution Coils – […]

Read More

Steam Coil Replacement

Having our customers prepared for this heating season is a top priority at Nationwide Coils! Last season caused major damage to heating coils, leaving them in need of major repair. Now is the time to stay ahead of old man winter and replace any existing heating coils that are beyond repair. We offer 24/7 customer […]

Read More

Munters HCUC Condenser Coils

Munters HCUC Condenser Coils located in this De-humidification unit has the tough task of constant operation throughout the year to control humidity inside the buildings they sit on top of. This constant operation over the year takes a heavy toll on the condenser coils within these units. The Munters HCUC is no exception, this unit has two condenser coils the standard condenser coil and the reactivation coil that uses the hot gas by product to dehumidify the outside air prior to entering the unit. These coils are constantly facing the tough conditions of operation in all climates with constant expansion and contraction of the copper tubes causing these them to degrade faster then most other coils. At Nationwide Coils we offer direct replacement coil solutions, with the ability to increase the materials of construction using a thicker copper tube wall to combat the rigorous conditions that the copper faces on a daily basis. This HCUC6030 unit has three different circuits in a face split configuration that all operate independently. This is different then the sister unit of the HCUW that has a single stage condenser coil that is either operating or not. Both units have a reactivation coil that are tall and narrow and are both 2 rows to efficiently control the humidity of the entering air. If you have any questions about coils in the Munters unit or any other unit contact us! We look forward to assisting you with whatever coil issues you may encounter out there. www.nationwidecoils.com

 

 

 

Read More

Lennox L-Series Condenser Coils

The other day we completed a site survey of a Lennox LCC180S roof top unit that has two single row condenser coils place in a V shape. They are long narrow coils supported on the top and bottom with galvanized brackets. The top portion of each coil are each individual circuits. The smaller bottom circuits […]

Read More